Default welcome msg!

sonoscape-s60

More Views

sonoscape-s60

 S60 system enhances flexibility and intelligence to a new level. Stable as ever, S60 improves its signal transmission and reception processors which leads to higher sensitivity and more accurate echo detection. What’s more, S60 is equipped with a wide range of transducers which adopt innovative technologies and therefore promises a confident diagnostic experience. Consistent quality performance across applications. 
 Enhanced with advanced imaging architecture and probe technologies, the system enlarges diagnostic capacity and quality across a wide range of applications 
 ・ μ-Scan
 ・Adaptive Multi-beam Imaging
 ・Dynamic Color
 ・Single Crystal Transducer
Ergonomic Design
 21,5” LED monitor with articulated arm
 13,3” Adjustable touch screen
 Rotatable and height adjustable control panel 
 Gel warmer
 Wireless Wi-Fi Connection

Description

Details

 ⇦  ⇩ S60 Images ⇩  Home 

 ⇦  ⇩ More Product information ⇩  Home 

 ⇦  ⇩ More Product information ⇩  Home 

 ⇦  ⇩ More Product information ⇩  Home 

 ⇦  ⇩ More Product information ⇩  Home 

 ⇦  ⇩ More Product information ⇩  Home 

SOFTWARE

  • OFF

  • ON

μ-Scan

μ-Scan uses realtime image processing algorithm to eliminate speckle and noise artifacts, enhancing tissue margins and borders by correcting discontinuity between different regions.

 ⇦  ⇩ S60 Clinic Images ⇩  Home 

Spatial Compound Imaging

Spatial Compound Imaging utilizes several lines of sight for optimal contrast resolution, speckle reduction and border detection. Is ideal for superficial and abdominal imaging with better clarity and improved continuity of structures.

S-Fetus

Acquisition of fully automatic Fetal Biometries (Available with BPD / AC / HC / FL / AFI / PL)

Automatic measurements and reports

3D Color

• More intuitive and realistic flow imaging

• Improved spatial resolution of vascular networks

• Several renderings for displaying different vascular information

Auto Face

It allows to delete the structures that interpose themselves to the profile of the fetal face.

SR-Flow

• High sensitivity with directional information

• Detection of micro-vascularization and weak flows

• More realistic hemodynamic flow

4D for Fallopian Tube

None

  • None

Micro F

The adaptive Matrix E filter effectively distinguishes the blood flow of individual tissues, artifacts and flows at low speed

The algorithm helps to visualize the low blood flow in a stable and continuous way

S-Live

Applies a virtual light source and advanced rendering technology that simulates the realistic skin effect.

STIC

• Rapid volume acquisition in 8-12 seconds

• Beat detection for fetal anatomical structures

• Useful diagnostic tool for fetal heart disease

S-Live Silouette

It allows to observe the internal anatomical structure of any volume previously acquired automatically.

Real Time 3D/4D

Real-time 3D imaging (4D) can intuitively show the three-dimensional structure in real time, together with the transverse and coronal planes of the various structures that we would normally not be able to acquire with 2D transducers.

S-Skeleton Depht

It automatically removes soft tissues to better visualize the fetal skeleton by adding a dedicated S-Depht map.

Inversion 4D

Inversion 4D provides a more in-depth evaluation of vascular and / or cystic structures by creating a three-dimensional volume of the anaechogenic structure.

S-Depth

Color map show the different depth.

Multi-Slice

Visualization of volumes in axial tomographic modality.

C-Plane

It allows to observe point-to-point the Coronal plane simultaneously with the acquisition plane and the transverse plane.

Auto NT

It allows to automatically measure the nuchal translucency.

AVC-Follicle

It allows you to calculate the number and volume of follicles automatically and quickly

Contrast Imaging

Software for the analysis and quantification of second generation MdC.

C-Xlasto

Elastography is a brand new non-invasive imaging technology. It allows the qualitative display of the elasticity of tissue according to a colorimetric scale chosen by the user. It allows to quantify the relationship between the region of interest (ROI) positioned on the suspected lesion and the surrounding tissue. 

Anatomic M.Mode

Up to 3 M-Mode lines displayed simultaneously and angled according to the needs of the operator

Auto EF

Automatically calculates the ejection fraction of the left ventricle through the automatic trace improving efficiency, accuracy and repeatability of cardiac examination.

Dynamic Color

HD-Flow. With Dynamic Color the sonographers can easily see in detail very small veins and slower velocities for detailed blood flow. 

IMT

Automatically identifies the intima and measures the thickness, improving the efficiency, accuracy and repeatability of the examination.

Panoramic Imaging

Real-time panoramic imaging allows visualization of larger anatomical structures than the transducer. The operator starts the sw and moves the transducer along the area of interest and the machine alligng the acquired images.

  • OFF

  • ON

Pulse Armonic Imaging

With PHI The harmonic signals are fully preserved without degradation of the acoustic information, which makes it possible to have high-level  image in the visualizing of small lesions.

TDI

TDI can obtain information myocardial velocity, direction and time so as to analyze cardiac function more intuitively. TDI allows you to quantitatively evaluate local myocardial motion, observe myocardial velocity of different cardiac part and estimate whether there is a local lesions, as well as evaluate the early diastolic function.

Trapezioid Imaging

It allows to widen the field of view of linear transducers.

Stress Echo S60

Stress echo is used to diagnose coronary heart disease, evaluate coronary reserve function and myocardial ischemia, and estimate myocardial viability, providing valuable diagnostic information for PCI&CABG.

Vis-Needle

By emphasizing the visualization of the needle, it increases the safety and accuracy of biopsy procedures and other interventional procedures including nerve blocks and vascular accesses.

 
 ⇦  ⇧ Top ⇧  Home 

CLINICAL IMAGES

None

 ⇦  ⇧ Top ⇧  Home